Growatt MIN 8.2KW 9KW 10KW 11.4KW Hybrid Solar Inverter
Datasheet |
MIN 8200TL-XH-US |
MIN 9000TL-XH-US |
MIN 10000TL-XH-US |
MIN 11400TL-XH-US |
Input Data (PV) |
||||
Max. Recommended PV Power(STC) |
16400W |
18000W |
20000W |
10000W |
DC/AC Ratio |
2 |
|||
Max. DC System Voltage |
600V |
|||
Startup Voltage |
50V |
|||
Full load voltage range |
170-500V |
190-500V |
210-500V |
235-500V |
Nominal Voltage |
360V |
|||
Operating Voltage Range |
50~550V |
|||
No. of MPPT |
4 |
|||
No. of PV Strings per MPPT |
2 |
|||
Max. Input Current per MPPT |
13.5A |
|||
Max. Short-circuit Current per MPPT |
16.9A |
|||
Input/Output Data (DC) |
||||
Battery Voltage Range |
360V~550V |
|||
Nominal DC Voltage |
400V |
|||
I/O DC Current |
24A/24A |
27A/27A |
30A/30A |
30A/30A |
I/O DC Power |
8500W |
9300W |
10300W |
10300W |
Battery Technology |
LFP |
|||
Battery Capacity per Module |
9.9kWh |
|||
Scalability |
Up to 4 |
|||
Output Data (AC) |
||||
AC Nominal Power@240V AC |
8200W |
9000W |
10000W |
11400W |
AC Nominal Power@208V AC |
7280W |
7900W |
8735W |
9880W |
Max. AC Apparent Power |
8200VA |
9000VA |
10000VA |
11400VA |
Nominal AC Voltage |
208V/240V |
|||
AC Voltage Range @208V AC @240V AC |
183V~229V/211V~264V |
|||
AC Grid Frequency |
50/60Hz |
|||
AC Grid Frequency Range |
45~65Hz |
|||
Max. Output Curren |
35A |
38A |
42A |
48A |
Power Factor(@Nominal Power) |
>0.99 |
|||
Adjustable Power Factor |
0.8 Leading~0.8 Lagging |
|||
THDi |
<3% |
|||
AC Grid Connection Type |
L1/L2/N/PE |
|||
Output Data (Backup) |
||||
AC Nominal Power |
8200W |
9000W |
10000W |
11400W* |
Max. AC Power Output |
9840VA |
10800VA |
12000VA |
13680VA |
Nominal AC Voltage |
240V |
|||
Max. Output Current |
41A |
45A |
50A |
57A |
THD |
5% |
|||
Efficiency |
||||
Max. Efficiency |
98.3% |
98.3% |
98.3% |
98.5% |
CEC Efficiency@240V AC |
97.5% |
97.5% |
97.5% |
97.5% |
CEC Efficiency@208V AC |
97.5% |
97.5% |
97.5% |
98.0% |
Protection Devices |
||||
DC Reverse-polarity Protection |
Yes |
|||
DC Switch |
Yes |
|||
DC Surge Protection |
Type II |
|||
Insulation Resistance Monitoring |
Yes |
|||
AC Surge Protection |
Type II |
|||
AC Short-circuitS Protection |
Yes |
|||
Ground Fault Monitoring |
Yes |
|||
Grid Monitoring |
Yes |
|||
Anti-islanding Protection |
Yes |
|||
Residual-current Monitoring Unit |
Yes |
|||
AFCI Protection |
Yes |
|||
General Data |
||||
Dimensions (W / H / D) |
15.8/25.2/7.4inch(400/638/187mm) |
|||
Weight |
45.2 lbs /20.5kg |
|||
Operating Temperature Range |
–13°F~+140°F (–25 °C ~ +60 °C) de-rating above 113°F |
|||
Altitude |
9843ft (3000m) |
|||
Internal Consumption at Night |
<1W (for PV inverter)/<5W (for storage inverter) |
|||
Cooling |
Natural Convection |
|||
Electronics Protection Degree |
NEMA4X (IP65) |
|||
Relative Humidity |
0~95% |
|||
Interfaces |
||||
RS485 |
Yes |
|||
WIFI/4G Communication |
Optional |
|||
Warranty: 10 Years |
Yes(optional for extended 15 and 20 years warranty) |
|||
Revenue Grade Meter |
ANSI C12.20 (meet 0.5% accuracy |
|||
IEEE1547, CA Rule21, Rule14 (HECO Compliant), FCC Part15 Class B, U L1741, UL1741SA,CSA C22.2, UL1699B, UL1741 CRD, UL 9540 |
||||
*11.4kW off-grid output requires both PV and battery power supply, and the battery itself has a rated off-grid power of 10kW. |